{"id":17957,"date":"2025-08-01T17:13:23","date_gmt":"2025-08-01T09:13:23","guid":{"rendered":"https:\/\/demo.maxmega.com\/?post_type=product&#038;p=17957"},"modified":"2025-10-21T10:25:04","modified_gmt":"2025-10-21T02:25:04","slug":"resi-shunt","status":"publish","type":"product","link":"https:\/\/demo.maxmega.com\/ch\/product\/resi-shunt","title":{"rendered":"RESI &#8211; Shunt"},"content":{"rendered":"<table style=\"width: 100%; margin-bottom: 30px;\">\n<tbody>\n<tr>\n<td style=\"width: 300px; vertical-align: top; text-align: center;\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/product\/resi\/shunt\/SHUNT.jpg\" alt=\"Precision Resistor\" width=\"300\" height=\"222\" \/><\/td>\n<td style=\"vertical-align: top;\">\n<h3 style=\"margin-bottom: 10px;\">Description<\/h3>\n<p style=\"text-align: justify; color: black;\">A DC shunt, which is actually a low resistance resistor, is usually used when a large current is to be measured. When current flows through the shunt, a millivolt voltage appears at both ends of it, so a millivolt voltmeter is used to measure this voltage to complete the calculation of high current.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"width: 100%; margin-top: 30px;\">\n<tbody>\n<tr>\n<td style=\"width: 50%;\" valign=\"top\">\n<h4 style=\"margin-bottom: 10px;\">Features<\/h4>\n<ul style=\"margin-top: 0; color: black;\">\n<li>Tight Tolerance (Class 0.1)<\/li>\n<li>Low Thermal EMF<\/li>\n<li>Low TCR<\/li>\n<li>Low PCR<\/li>\n<li>Maximum Rated Current 100KA<\/li>\n<\/ul>\n<\/td>\n<td style=\"width: 50%;\" valign=\"top\">\n<h4 style=\"margin-bottom: 10px;\">Applications<\/h4>\n<ul style=\"margin-top: 0; color: black;\">\n<li>BMS<\/li>\n<li>Eletric Powder<\/li>\n<li>Industrial Controls<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<style>\n.table-custom {\n  width: 100%;\n  border-collapse: collapse;\n}\n.table-custom th,\n.table-custom td {\n  border: 1px solid #ccc;\n  padding: 10px;\n  text-align: center;\n  vertical-align: middle;\n  color: black;\n}\n.table-custom th {\n  background-color: grey;\n  color: white;\n}\n.table-custom td.description {\n  text-align: left;\n}\n<\/style>\n<table class=\"table-custom\">\n<thead>\n<tr>\n<th>Series<\/th>\n<th>Image<\/th>\n<th>Description<\/th>\n<th>Resistance Range<\/th>\n<th>Tolerance<\/th>\n<th>TCR<\/th>\n<th>Rated Current<\/th>\n<th>Output Voltage<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>RTBS0010<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/product\/resi\/shunt\/RTBS0010.jpg\" alt=\"RTBS0010\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 10A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>5m\u03a9-7.5m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>10A<\/td>\n<td>50mV-75mV<\/td>\n<\/tr>\n<tr>\n<td>RTBS0025<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/product\/resi\/shunt\/RTBS0025.jpg\" alt=\"RTBS0025\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 25A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>5m\u03a9-7.5m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>25A<\/td>\n<td>50mV-75mV<\/td>\n<\/tr>\n<tr>\n<td>RTBS0050<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/product\/resi\/shunt\/RTBS0050.jpg\" alt=\"RTBS0050\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 50A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>1m\u03a9-1.5m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>50A<\/td>\n<td>50mV-75mV<\/td>\n<\/tr>\n<tr>\n<td>RTBS0100<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/product\/resi\/shunt\/RTBS0100.jpg\" alt=\"RTBS0100\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 100, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>0.5m\u03a9-0.75m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>100A<\/td>\n<td>50mV-75mV<\/td>\n<\/tr>\n<tr>\n<td>RTBS0200<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/product\/resi\/shunt\/RTBS0200.jpg\" alt=\"RTBS0200\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 200, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>0.25m\u03a9-0.375m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>200A<\/td>\n<td>50mV-75mV<\/td>\n<\/tr>\n<tr>\n<td>RTBS0300<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/product\/resi\/shunt\/RTBS0300.jpg\" alt=\"RTBS0300\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 300, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>0.167m\u03a9-0.25m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>300A<\/td>\n<td>50mV-75mV<\/td>\n<\/tr>\n<tr>\n<td>ARCS6918-L050<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/ARCS6918-L050-1.jpg\" alt=\"ARCS6918-L050\" width=\"80\" \/><\/td>\n<td class=\"description\">Economical Mn-Cu alloy shunt, the maximum rated current is 700A, and the resistance is 50 \u03bc \u03a9<\/td>\n<td>50\u03bc\u03a9<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b1100ppm<\/td>\n<td>700A<\/td>\n<td>35mV<\/td>\n<\/tr>\n<tr>\n<td>ARCS6918-L100<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/ARCS6918-L100-1.jpg\" alt=\"ARCS6918-L100\" width=\"80\" \/><\/td>\n<td class=\"description\">Economical Mn-Cu alloy shunt, the maximum rated current is 500A, and the resistance is 100 \u03bc \u03a9<\/td>\n<td>100\u03bc\u03a9<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b1100ppm<\/td>\n<td>500A<\/td>\n<td>50mV<\/td>\n<\/tr>\n<tr>\n<td>ARCS8518-L050<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/ARCS8518-L050-1.jpg\" alt=\"ARCS8518-L050\" width=\"80\" \/><\/td>\n<td class=\"description\">Economical Mn-Cu alloy shunt, the maximum rated current is 840A, and the resistance is 50 \u03bc \u03a9<\/td>\n<td>50\u03bc\u03a9<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b1100ppm<\/td>\n<td>840A<\/td>\n<td>40mV<\/td>\n<\/tr>\n<tr>\n<td>ARCS8518-L100<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/ARCS8518-L100-1.jpg\" alt=\"ARCS8518-L100\" width=\"80\" \/><\/td>\n<td class=\"description\">Economical Mn-Cu alloy shunt, the maximum rated current is 600A, and the resistance is 100 \u03bc \u03a9<\/td>\n<td>100\u03bc\u03a9<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b1100ppm<\/td>\n<td>600A<\/td>\n<td>60mV<\/td>\n<\/tr>\n<tr>\n<td>ARCS8518-L250<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/ARCS8518-L250-1.jpg\" alt=\"ARCS8518-L250\" width=\"80\" \/><\/td>\n<td class=\"description\">Economical Mn-Cu alloy shunt, the maximum rated current is 316A, and the resistance is 250 \u03bc \u03a9<\/td>\n<td>250\u03bc\u03a9<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b1100ppm<\/td>\n<td>316A<\/td>\n<td>75mV<\/td>\n<\/tr>\n<tr>\n<td>ARCS8536-L025<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/ARCS8536-L025-1.jpg\" alt=\"ARCS8536-L025\" width=\"80\" \/><\/td>\n<td class=\"description\">Economical Mn-Cu alloy shunt, the maximum rated current is 1410A, and the resistance is 25 \u03bc \u03a9<\/td>\n<td>25\u03bc\u03a9<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b1100ppm<\/td>\n<td>1410A<\/td>\n<td>50mV<\/td>\n<\/tr>\n<tr>\n<td>ARCS8536-L050<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/ARCS8536-L050-1.jpg\" alt=\"ARCS8536-L050\" width=\"80\" \/><\/td>\n<td class=\"description\">Economical Mn-Cu alloy shunt, the maximum rated current is 1000A, and the resistance is 50 \u03bc \u03a9<\/td>\n<td>50\u03bc\u03a9<\/td>\n<td>\u00b10.5%<\/td>\n<td>\u00b1100ppm<\/td>\n<td>1000A<\/td>\n<td>50mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS10K0<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS10K0-1.jpg\" alt=\"RTCS10K0\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 10000A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR<\/td>\n<td>5\u03bc\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>10000A<\/td>\n<td>50mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS16K0<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS16K0-1.jpg\" alt=\"RTCS16K0\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 16000A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR<\/td>\n<td>3.125\u03bc\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>16000A<\/td>\n<td>50mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS20K0<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS20K0-1.jpg\" alt=\"RTCS20K0\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 20000A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR<\/td>\n<td>2.5\u03bc\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>20000A<\/td>\n<td>50mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS0050<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS0050-1.jpg\" alt=\"RTCS0050\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 50A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR<\/td>\n<td>1m\u03a9-1.5m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>50A<\/td>\n<td>50mV-75mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS0100<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS0100-1.jpg\" alt=\"RTCS0100\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 100A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR<\/td>\n<td>0.5\u03a9m-0.75m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>100A<\/td>\n<td>50mV-75mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS0200<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS0200-1.jpg\" alt=\"RTCS0200\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 200A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR<\/td>\n<td>0.25\u03a9m-0.375m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>200A<\/td>\n<td>50mV-75mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS0300<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS0300-1.jpg\" alt=\"RTCS0300\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 300A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>0.167m\u03a9-0.25m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>300A<\/td>\n<td>50mV-75mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS0500<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS0500-1.jpg\" alt=\"RTCS0500\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 500A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>0.1m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>500A<\/td>\n<td>50mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS1000<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS1000-1.jpg\" alt=\"RTCS1000\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 1000A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>0.05m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>1000A<\/td>\n<td>50mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS2000<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS2000-1.jpg\" alt=\"RTCS2000\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 2000A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>0.025m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>2000A<\/td>\n<td>50mV<\/td>\n<\/tr>\n<tr>\n<td>RTCS5000<\/td>\n<td><img decoding=\"async\" src=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/10\/RTCS5000-1.jpg\" alt=\"RTCS5000\" width=\"80\" \/><\/td>\n<td class=\"description\">Mn-Cu alloy precision shunt, rated current 5000A, sensing tolerance \u00b10.1%,low thermal EMF, low TCR, with base<\/td>\n<td>0.01m\u03a9<\/td>\n<td>\u00b10.1%<\/td>\n<td>\u00b120ppm<\/td>\n<td>5000A<\/td>\n<td>50mV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Description A DC shunt, which is actually a low resistance resistor, is usually used when a large current is to be measured. When current flows through the shunt, a millivolt voltage appears at both ends of it, so a millivolt voltmeter is used to measure this voltage to complete the calculation of high current. Features&hellip; <br \/> <a class=\"read-more\" href=\"https:\/\/demo.maxmega.com\/ch\/product\/resi-shunt\">Read more<\/a><\/p>","protected":false},"featured_media":17982,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[27],"product_tag":[],"class_list":["post-17957","product","type-product","status-publish","has-post-thumbnail","hentry","pwb-brand-resi","product_cat-resistors-and-potentiometers"],"brands":[{"id":439,"name":"RESI","slug":"resi"}],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>RESI - Shunt - Maxmega<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/demo.maxmega.com\/ch\/product\/resi-shunt\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RESI - Shunt - Maxmega\" \/>\n<meta property=\"og:description\" content=\"Description A DC shunt, which is actually a low resistance resistor, is usually used when a large current is to be measured. When current flows through the shunt, a millivolt voltage appears at both ends of it, so a millivolt voltmeter is used to measure this voltage to complete the calculation of high current. Features&hellip; Read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/demo.maxmega.com\/ch\/product\/resi-shunt\/\" \/>\n<meta property=\"og:site_name\" content=\"Maxmega\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-21T02:25:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/08\/SHUNT.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"550\" \/>\n\t<meta property=\"og:image:height\" content=\"408\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\">\n\t<meta name=\"twitter:data1\" content=\"3 \u5206\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/demo.maxmega.com\/en\/#website\",\"url\":\"https:\/\/demo.maxmega.com\/en\/\",\"name\":\"Maxmega\",\"description\":\"Electronics Pte Ltd\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/demo.maxmega.com\/en\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/demo.maxmega.com\/product\/resi-shunt#primaryimage\",\"inLanguage\":\"zh-Hans\",\"url\":\"https:\/\/demo.maxmega.com\/wp-content\/uploads\/2025\/08\/SHUNT.jpg\",\"width\":550,\"height\":408},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/demo.maxmega.com\/product\/resi-shunt#webpage\",\"url\":\"https:\/\/demo.maxmega.com\/product\/resi-shunt\",\"name\":\"RESI - Shunt - Maxmega\",\"isPartOf\":{\"@id\":\"https:\/\/demo.maxmega.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/demo.maxmega.com\/product\/resi-shunt#primaryimage\"},\"datePublished\":\"2025-08-01T09:13:23+00:00\",\"dateModified\":\"2025-10-21T02:25:04+00:00\",\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/demo.maxmega.com\/product\/resi-shunt\"]}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/demo.maxmega.com\/ch\/wp-json\/wp\/v2\/product\/17957","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/demo.maxmega.com\/ch\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/demo.maxmega.com\/ch\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/demo.maxmega.com\/ch\/wp-json\/wp\/v2\/comments?post=17957"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/demo.maxmega.com\/ch\/wp-json\/wp\/v2\/media\/17982"}],"wp:attachment":[{"href":"https:\/\/demo.maxmega.com\/ch\/wp-json\/wp\/v2\/media?parent=17957"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/demo.maxmega.com\/ch\/wp-json\/wp\/v2\/product_cat?post=17957"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/demo.maxmega.com\/ch\/wp-json\/wp\/v2\/product_tag?post=17957"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}